Accessory | Battery Ballast | Fluorescent 3000 Lumens [EB-30]
Utilize everyday existing fluorescent lighting as emergency lighting. Emergency battery ballasts allow a linear or compact fluorescent (CFL) fixture to be used during both normal and emergency operation. In the event of a power failure, the emergency battery ballast operates the fixture, powering the lamp for a minimum of 90 minutes from the built-in backup battery.
Use with 17-215 watts single pin or bi-pin fluorescent lamps (T5, T8, T9, T10 or T12) for 90 minutes including U-shaped, HO, VHO, circline, twin, quad and triple twin-tube compacts.
UL Listed
This item has been tested and meets safety standards imposed by the Underwriters Laboratories (UL).
LED Lighting
This unit uses energy efficient and long lasting LED's.
FEATURES
- UL Listed for factory or field installation
- Emergency illumination time exceeds the National Electrical Code (NEC), Life Safety Code (NFPA) and UL 90-minute requirements
- One- or two-lamp operation
- Compatible with most one, two, three or four lamp electronic, standard and dimming AC ballasts
- Does not affect normal fixture operation
- May be used with either a switched or unswitched fixture
- May be installed on top of or remote from the fixture
- Not recommended with fixtures where the ambient temperature may fall below 0°C.
- Charging indicator light and double-pole Push-to-test switch included
SPECIFICATIONS
Dimensions | |
---|---|
Width | 5.5" |
Height | 1.75" |
Length | 16.25" |
Weight | 9.00 lb |